Text of page 17
UNCLASSIFIED/LEOR OFFICIAL USE ONLY
Our implementation of the FSL utilizes an IPM whose dielectric permittivity tensor is
anisotropic and contains positive and negative components: 81 > 0,8, < 0, where parallel
refers to the IPM/object interface. We have already fabricated such IPMs using SiOz-
SiC-SiOz multi-layer, and are investigating other approaches involving selectively-doped
semiconductor multi-layers similar to the ones used by Gmachl's group at Princeton.
SiOz-SiC-SiOz multi-layers are produced in-house (with SiC films shipped by Professor
Ferro from University of Lyons, France). The main function of the IPM is to propagate
sub-diffraction waves (k > c/c) with as little decay as possible. That happens because
these sub-diffraction waves are no longer evanescent: ki~-ka/& > 0. It is
demonstrated experimentally that there exists a frequency range for which sub-
diffraction waves propagate through the IPM with less attenuation than the radiation-
zone waves (k <c/c), see Figure 11.
10*'
MCT detector on optical rail
Lock-in
amplifier
D, = 2.74 um
100 mm Au
220 mm SiO,
440 mm SiC
220 mm SiO
00 nm Au
D, = 2.94 uml
500 mm
Optical
chopper
Mid-IR
CO, laser
10.66 um-
11.31 um
Transmission (normalized to incident laser power)
m=0
otder
+2 order
+3% order
-1 " 06d:
-2* order
10
m=1
K* = 2mm / D,
crossover
10°
390100
m=2
10
m=3
> 0,8. <0
10,%
10.6
10.7 10.8 10.9
11.0
11.1
11.2
11.3
1.4
Wavelength (um)
Figure 11. First Experimental Demonstration of Propagating Sub-Diffraction Waves in the IPM. (Left):
Experimental setup demonstrating how sub-diffraction waves are launched into the IPM using FIB-fabricated sub-
wavelength grating. Because the periods of the bottom ("launching") and top ("transforming") gratings are
different, far-field observation of different harmonics of the bottom grating is enabled. (Right): Experimental
results: the first sub-diffraction harmonic of the grating (green line) becomes stronger than the zeroth radiation-
zone harmonic of the grating (blue line) in the region where & 1 > 0, 8, < 0.
Once sub-diffraction waves propagate through the IPM, they can diffract on the image-
releasing grating (see Figure 10) and be radiated out into the far field. A detector array
can be used to collect the signal and reconstruct the image. Unfortunately, different
wave numbers k, of the object are directed into the same detector and produce an
ambiguity in extracting their respective amplitudes A(k). This ambiguity is illustrated
by Figure 10: wave numbers k, = Ak + 27 / D and kz = Ak + 4* / D are directed to the
same far-field detector. Simply put, a single number (intensity of light with the wave
number Ak < / cincident on the detector) is insufficient for determining two scattering
13
UNCLASSIFIED/LEOR OFFICIAL USE ONLY