DOW-UAP-D141

AAWSAP DIRD, Metamaterials for Aerospace Applications, April 2010, page 18

One page of a U.S. government record released under PURSUE, shown on its own with its text. The record page has the whole document, its catalog details and the scan.

Page
18 of 38
Agency
Department of War
Released
Release 06, September 18, 2026

Text of page 18

UNCLASSIFIED/FOR DEFICIAL USE ONET amplitudes ( A(k,) and A(kz) ). Therefore, a new concept has to be developed, and the multi-detector technique is such a concept. The concept requires two detectors and two coherent laser beams. The two beams are formed using a beam-splitter and a variable delay line imparting a phase shift to the two beams (see the actual experimental photograph in Figure 13 where the beam- splitter BS and the Delay Line are shown). We have theoretically demonstrated that the intensity dependences of the two detector intensities 1,(y) and 12(y) as a function of the phase delay y provides enough information to recover both A(k) and A(kz). D, Unequal grating phase interference: 0h, 2nd orders 144 points = 300: D, = 2.74 um 100 nm Au 220 mm SiO, 440 nm SiC 220 mm SiO, 100 mm Au D, = 2.94 um D • B 500 nm Detector intensity (normalized to oh order transmission 4167 Delay Line 20 40 60 80 100 120 140 160 180 200 220 240 Example "micrometer position" not correlated to phase Figure 12. (Left): Schematic for 2-Beams/2-Detectors Interferometric Measurement. (Right): Numerical Simulation: intensity on the two detectors as a function of the phase delay between beams A and B produced by the interference between the zeroth and first diffractive orders of the bottom diffractive grating (numerical simulation). The second detector provides the necessary second data point which is necessary for separating the contributions of different diffractive orders. Two sets of experiments demonstrating the feasibility of the concept are conducted. None of these experiments constitutes imaging per se. However, without demonstrating the two key milestones described below, proper imaging experiments cannot be attempted. The first milestone involves demonstrating that IPM indeed supports propagating (non- evanescent) sub-diffraction waves. Figure 11 shows the experimental schematic (left panel) and experimental results. The bottom grating "imprints" its Fourier components (zeroth, first, second, third, and so forth) onto the incident laser pulse thereby generating electromagnetic waves that are launched into the SiC-based IPM. The zeroth harmonic is inside the radiation zone (that is, it is not sub-diffraction), while the first, second, and so forth sub-diffraction. These EM waves scatter off the top grating having a slightly different period and are released into the far field. Because the direction in which waves are released depend on the Fourier harmonic's number, we can experimentally separate and measure them. Clearly, the relative magnitudes of these diffractive orders dramatically vary as a function of the laser wavelength. For example, the zeroth diffraction order clearly dominates in the & < 0,8, > 0 frequency range. However, in the &1 > 0, 8, < Ofrequency range the first diffractive order becomes larger 14 UNCLASSIFIED/LEOR DEFICIAL USE ONLY

Machine-read (OCR) from the scan by this archive; it can contain errors. The scan is the record.

Image from page 18 of DOW-UAP-D141, as released by war.gov
Image from page 18 of the PDF. Open the scan to see the whole page.

Cite this page

U.S. Department of War. "AAWSAP DIRD, Metamaterials for Aerospace Applications, April 2010" (DOW-UAP-D141). PURSUE Release 06, U.S. Department of War, September 18, 2026. https://www.war.gov/medialink/ufo/sept-18/release-06/assets/DOW-UAP-D141_AAWSAP-DIRD-Metamaterials-for-Aerospace-Applications-April-6-2010.pdf. Declassified UAP, page 18, https://declassifieduap.org/r/dow-uap-d141-aawsap-dird-metamaterials-for-aerospace-applications-april-2010/p/18. Accessed November 28, 2026.

This address shows page 18 on its own; /r/dow-uap-d141-aawsap-dird-metamaterials-for-aerospace-applications-april-2010?page=18 opens the same page in the full reader. Both stay. How to cite.