DOW-UAP-D141

AAWSAP DIRD, Metamaterials for Aerospace Applications, April 2010, page 20

One page of a U.S. government record released under PURSUE, shown on its own with its text. The record page has the whole document, its catalog details and the scan.

Page
20 of 38
Agency
Department of War
Released
Release 06, September 18, 2026

Text of page 20

UNCLASSIFIED/FOR DEFICIAL USE ONLY Applications to Circuits and Waveguide Miniaturization: Slowing Down and Manipulating Electromagnetic Pulses (EMP) Using Advanced Metamaterials Given the space constraints of an advanced aerospace platform and the amount of the useful payload that has to be carried, it is very important that every optical and microwave component be as small as possible. Because of the very large speed of light, there is a natural limit to how small such components can be made. Any structure capable of processing EMPs (be those optical, THz, or microwave) of temporal duration r must be at least L = clong. For example, a 1 ns microwave pulse can be manipulated inside a device that is at least 1 ft long. Pulse manipulation can be understood very broadly by pulse compression, frequency shifting, harmonics generation, or other. For aerospace communications systems, it may be very desirable to have the ability to manipulate the format of EMPs, (that is, to change their frequency, duration, and repetition rate). Slowing down or even stopping the EMP can circumvent the length requirement if the group velocity is reduced to v, <<c, and thus the required length is L = vT. meta plasma C 000 СТ B(t) go t (CT)/go Ng1 meta Figure 14. Schematic of Pulse Compression in Magnetized Plasma. A radiation pulse with initial frequency 0, and duration T slows down in the plasma to a group velocity go << C. Adiabatic spatially uniform variation of the magnetic field changes the radiation frequency to 0, and increases the group velocity to V1 >> V go • The emerging pulse is compressed to T, = Tvso / Vg1 • (Reference 29) An example of the pulse slowing down and subsequent manipulation is first discussed in Reference 29 in the somewhat esoteric context of magnetized plasma. Pulse duration, frequency, and (for multiple pulses) repetition rate can be controlled by storing (or slowing down) electromagnetic waves and subsequently changing the system's parameters. The essence of the compact pulse manipulator is shown in Figure 14. The pulse is slowed down inside the compact plasma device and manipulated by changing the magnitude of the magnetic field. The advantage of slowing the pulses down is three-fold. First, the device can be made smaller, resulting in size savings. Second, the temporal scale on which the system has to be manipulated is lengthened because the pulse is moving slowly. Finally, the potentially large ratio between g, >> Ngo results in the more dramatic dynamic range of possible pulse compression ratios. Plasma-based 16 UNCLASSIFIED/LEOR OFFICIAL USE ONLY

Machine-read (OCR) from the scan by this archive; it can contain errors. The scan is the record.

Image from page 20 of DOW-UAP-D141, as released by war.gov
Image from page 20 of the PDF. Open the scan to see the whole page.

Cite this page

U.S. Department of War. "AAWSAP DIRD, Metamaterials for Aerospace Applications, April 2010" (DOW-UAP-D141). PURSUE Release 06, U.S. Department of War, September 18, 2026. https://www.war.gov/medialink/ufo/sept-18/release-06/assets/DOW-UAP-D141_AAWSAP-DIRD-Metamaterials-for-Aerospace-Applications-April-6-2010.pdf. Declassified UAP, page 20, https://declassifieduap.org/r/dow-uap-d141-aawsap-dird-metamaterials-for-aerospace-applications-april-2010/p/20. Accessed November 28, 2026.

This address shows page 20 on its own; /r/dow-uap-d141-aawsap-dird-metamaterials-for-aerospace-applications-april-2010?page=20 opens the same page in the full reader. Both stay. How to cite.