Text of page 15
UNCLASSIFIED//FOR eFFrE
AL USE ONLY
pulses (STT switching). Figure 9 shows scanning transmission x-ray microscopy
(Reference 53) images of in-plane components of magnetization M - Mx in panel (a)
and My in panel (b)—in the free CoFe layer (indicated by blue ellipse) of a 100x150-nm2
magnetic nanopillar. The images were obtained by scanning a focused (diameter ~ 30
nm) circularly polarized x-ray beam across the Cofe layer, with the photon energy
tuned to the characteristic Co L3 resonance to provide magnetic contrast through the x-
ray magnetic circular dichroism effect (Reference 54), and by monitoring transmission
of the x-rays as a function of the position x, y with a fast avalanche detector. The M-
vector field of the free layer can be reconstructed from the measured Mx and My
components as illustrated in Figure 9c, and the ultrafast x-ray microscopy technique
provided a means to monitor this field as a function of time with ~100-picosond
resolution. The spatial resolution of the technique is set by the spot size of the x-ray
beam (~30 m) and currently limits its application to spintronic devices > 100 mm in
size (Reference 52). Potentially, however, technical development of the ultrafast x-ray
microscopy may lead to an ultimate technique for STT studies that can probe the M-
vector field on the nanometer length scale with picosecond time resolution.
100 nm,
(a)
(b)
(c)
Figure 9. Scanning transmission x-ray microscopy images of Mx (a) and My (b) components of
magnetization M combine into the vector field (c), which represents the direction of M in the plane of
the CoFe free layer. (Reference 52)
3.3 STT APPLICATIONS
The STT method to manipulate magnetic moments by an electrical current offers
unprecedented spatial and temporal control of spin distributions and attracts
considerable attention because of its potential application in a broad range of
technologies. The perspective of STT for GHz communication applications and in
magnetic recording technology is discussed.
The STT application in high-frequency technologies is based on the spin-transfer-
induced precession of spins. The previous section discussed how precession of
magnetization in GMR devices can convert a de current input into an ac voltage output.
The frequency of this output can be tuned from a few GHz to > 100 GHz by changing
the applied magnetic field and/or the de current, effectively resulting in a current-
controlled oscillator for use in practical microwave circuits. Hence, the STT effect in
10
UNCLASSIFIED/ /FOR OFFICIAL USE ONLY