UNCLASSIFIED//FOR OFFIETAL USE ONLY
The basic principle of this detection method, shown in Figure 2.5, is common to most
NAA but is now specialized for detecting the basic elements in the land mines. Key
design considerations are the source strength required, the neutron energy desired (i.e.
D-D vs D-T fusion) and the type and location of neutron and x-ray detectors (from
Reference 2.7).
How to Detect Landmine
Neutron yield of -10® is required
neutron
source
y-ray
detector
neutron
detector
captured
y-ray
neutron
ray
Atomic ratio of TNT explosive
H
C
N
3
7
3
6
back
scattered
neutron
Atomic ratio of explosives fixed
thermal
neutron
landmine
(explosive)
neutron-captured y ray (kind of LM)
H(n,y) • • • 2.22 MeV y ray emission
N(n, y) • • • 10.83 MeV y ray emission
back-scattered neutron (existence of LM)
H(n, n') • • • H scatter neutron
Figure 2.5. Scheme for Landmine Detection Using a Hybrid Magnetron Type IEC Neutron
Source (From Reference 2.7)
The IEC developed for this work used a magnetron ion generation technique to improve
the neutron production efficiency (Reference 2.6). A built-in magnetron discharge ion
source was installed in the IEC. With the magnetron discharge, ions are produced in the
vicinity of the vacuum chamber (anode) at negative electric potential. Therefore, the
ions produced are expected to have nearly full energy corresponding to the applied
voltage to the IEC cathode but slightly smaller energy than the anode potential. This
prevents them from hitting the anode of the opposite side improving both fusion
reaction rate and ion recirculation life. (Note that this approach is yet another way to
address the problem of preventing ions created externally from escaping after entering
the potential well. The technique here is to use the internal source to create the ions at
a potential level less than the height of the potential well).
In addition to an internal source, the magnetron can produce ample ion current to
maintain the discharge under low-pressure conditions. Ions generated in the ion source
are attracted by the IC central cathode because of its high negative electric potential.
Therefore, the Kyoto investigators expected that a higher applied voltage would
increase the extraction current, giving a higher IE cathode current. However, it was
18
UNCLASSIFIED//FOR
AL USE ONLY