UNCLASSIFIED//FOR OFFICE AL USE ONLY On other McDonnell hypersonic configurations with all-movable control surfaces, the interface between the fin and the body became a critical heating issue for the rotating shaft attaching the fin to the body. This was an area of concern on this vehicle, and specially instrumented fins were installed to measure the local heating. Again, the thermographic phosphors were used to map the heating. Figure 20 shows the model in Figure 17 at a maximum 48-degree angle of attack. Fin heating distributions were made at 16-, 24-, 34-, and 48-degree angles of attack12 and are shown in Figure 21. The brighter the phosphor is, the lower its temperature is (the phosphor darkens as the surface temperature increases). So the area adjacent to the body is at a lower temperature than on the fin. In fact, examining Figure 21 shows that for all angles of attack tested, there was always the cool layer adjacent to the body. So the fin attachment journal/shaft would not be a thermal problem. At angles of attack lower than 16 degrees, the heating became less intense. This tail configuration of a fixed anhedral lower fin with trailing edge controls and an all-movable upper fin provided the control authority over the entire mach range required for stability and control and did not have a thermodynamic issue with fin attachment heating. a = 48° FIG. 6. ISODENSITRACER maps for lifting body tail fin for four ANGlES Of AttACk; CONtOUrs ShOW qUOCAL/qUEFERENCE: Figure 20. Thermographic Phosphor Image of Model 176 at Near-Maximum Angle of Attack Figure 21. From L/D Maximum to Maximum Angle of Attack, There is Always a Cool Sublayer Adjacent to the Wall With 1960 materials and manufacturing methods, about 95 percent of the aerodynamic heating was radiated to space, about 2.5 percent was retained in the shingles, and about 2.5 percent was transferred into the titanium tank/primary structure. Using Goodrich Aerospace's standoff/attachment techniques developed for the X-33, today around 0.5 to 1 percent of the aerodynamic heating would be transferred into the titanium tank/primary structure. The shingle material would also be better today. Figure 22 shows a silicon carbide matrix reinforced with silicon carbide fibers that was shown at the 1988 Paris Air Show. A combustor of this material was operated at 3,000 • F continuously for a number of days at SEP's Bordeaux plant, as witnessed by the author. Unfortunately, SEP was subsequently taken over by another company and promptly closed. The parts manufacturing at Bordeaux was truly impressive to someone in space systems but too costly to a subsonic round engine manufacturer. 20 UNCLASSIFIED//FOR OFFICIAL USE ONLY

Machine-read (OCR) from the scan by this archive; it can contain errors. The scan is the record.

Image from page 27 of DOW-UAP-D124, as released by war.gov
Image from page 27 of the PDF. Open the scan to see the whole page.

Cite this page

U.S. Department of War. "AAWSAP DIRD, Space Access: Where We’ve Been and Where We Could Go, March 2010" (DOW-UAP-D124). PURSUE Release 06, U.S. Department of War, September 18, 2026. https://www.war.gov/medialink/ufo/sept-18/release-06/assets/DOW-UAP-D124_AAWSAP-DIRD-Space%20Access-Where-Weve-Been-and-Where-We-Could-Go-March-8-2010.pdf. Declassified UAP, page 27, https://declassifieduap.org/r/dow-uap-d124-aawsap-dird-space-access-where-weve-been-and-where-we-could-go-march-2010/p/27. Accessed November 28, 2026.

This address shows page 27 on its own; /r/dow-uap-d124-aawsap-dird-space-access-where-weve-been-and-where-we-could-go-march-2010?page=27 opens the same page in the full reader. Both stay. How to cite.