Text of page 167

28. J-9,20 Dec 60, Response Mode 4, Flight Phase 2: No Stage-Il ignition due to failure of gas generator to start. 29. J-10, 20 Jan 61, Response Mode 4, Flight Phase 2: No Stage-Il operation due to erroneous signal that appeared at umbilical disconnect. Impact some 420 miles downrange. 32. J-12, 3 Mar 61, Response Mode 4, Flight Phase 2: Stage-II terminated prematurely after 54-second burn, apparently due to failure of pump drive assembly. Impact was 730 miles downrange. 34. J-15, 31 Mar 61, Response Mode 4, Flight Phase 1: Booster shut down prematurely at 74 seconds. Missile subsequently tumbled and broke up. 37. M-1, 24 Jun 61, Response Mode 4T, Flight Phase 2: Stage II engine shut down prematurely after 12 seconds of operation due to loss of Stage II hydraulic power. Loss of hydraulic power occurred during Stage I flight, so failure led to loss of control of sustainer and vernier actuators, producing excessive missile motion and tumbling. 42. M-3,7 Sep 61, Response Mode 5, Flight Phase 2: A transient in guidance computer at 218.35 seconds (SECO at 297.7 seconds) caused impact 20 miles short and 2.8 miles left of target. 45. M-4, 6 Oct 61, Response Mode 5, Flight Phase 2: A one-bit error in the W velocity accumulation caused impact 86 miles short and 14 miles right of target. 50. M-6, 15 Dec 61, Response Mode 4, Flight Phase 2: Start signal for Stage II was not generated. Stage II did not ignite. 51. I, 20 Jan 62, Response Mode 4, Flight Phase 2: Missile self-destructed, apparently after Stage 2 failed to ignite. A backup automatic fuel-cutoff signal was sent at 248 Seconds. 53. 1, 23 Feb 62, Response Mode 4, Flight Phase 2: Missile self-destructed, apparently after Stage 2 failed to ignite. A backup automatic fuel cutoff signal was sent at 240 Seconds. 56. N-1, 7 Jun 62, Response Mode 4, Flight Phase 2: Sustainer engine performance was subnormal due to reduced oxidizer flow through the gas generator. RSO terminated flight after a prolonged sustainer burn. Impact only 1100 miles downrange. 58. N-4, 25 July 62, Response Mode 4, Flight Phase 2: After about 60 seconds of Stage Il burn, a fuel leak between the thrust chamber valve and the injector resulted in a 9/10/96 158 RTI

Machine-read (OCR) from the scan by this archive; it can contain errors. The scan is the record.

Cite this page

U.S. Department of War. "Department of the Air Force Report, 1996" (DOW-UAP-D048). PURSUE Release 01, U.S. Department of War, May 8, 2026. https://www.war.gov/medialink/ufo/release_1/dow-uap-d48-report-september-1996.pdf. Declassified UAP, page 167, https://declassifieduap.org/r/dow-uap-d048-department-of-the-air-force-report-1996/p/167. Accessed November 28, 2026.

This address shows page 167 on its own; /r/dow-uap-d048-department-of-the-air-force-report-1996?page=167 opens the same page in the full reader. Both stay. How to cite.